Generator Hire Perth
We hire diesel generators for Perth sites that have no mains power yet, or need more than the supply can give them, or cannot afford to stop when the power goes out.
Diesel site power for builds, events and outages
Sized on starting current, not just the sum of the nameplates
Single phase and three phase, silenced units available
Delivered, positioned and fuelled ready to run

Why Adding Up The Labels Gets It Wrong
Anything with a motor in it, a compressor, a pump, a saw, a hoist, draws several times its running current for the moment it starts. A generator sized on running load alone will sag or trip every time one of them kicks in.
Generators are rated in kVA rather than kW, and the two are not interchangeable. kVA is the apparent power the machine can deliver, kW is the real work it does, and the gap between them is the power factor of what you plug in.
Sizing is the whole job. A generator picked on the sum of the labels will trip the moment something with a motor in it starts, because starting current is several times running current. Tell us what plugs in and we will size it on the real load.
Delivered, positioned and fuelled to start. On longer hires we can arrange refuelling rather than leaving it to whoever is on site that morning.
What We Need To Size It
- Every item that will run at once, with its rating from the plate
- Which of those have motors, and whether they start together or staggered
- Whether you need single phase, three phase or both
- How many hours a day it runs, which decides tank size and refuelling
- How close it sits to a boundary or a neighbour, which decides how quiet it has to be
Oversizing Has Its Own Problem
A diesel generator run far below its rated load for long periods wet-stacks: unburnt fuel builds up in the exhaust and fouls the engine. Bigger is not automatically safer. Size it to the load with sensible headroom rather than picking the largest unit on the list.
Not Sure Which Machine The Job Needs? Ask Us.
Call Us NowWhat Perth Hires Generators For
Builds
No Supply Yet
Power on site before the connection is energised
Events
Temporary Load
Marquees, stalls, lighting and sound with nothing nearby
Outages
Keep Running
Standby cover when the mains drops out
Remote
Off The Grid
Regional and remote WA jobs with no supply at all
The commonest one in Perth is the residential or small commercial build that is framed and roofed but not yet connected. A generator keeps the trades working through the gap rather than everyone standing around waiting on Western Power.
Ask About Noise Before You Book
A silenced unit costs more and is worth it on a suburban block. Standard open units are loud enough to become a neighbour problem and, on some sites, a council one. Tell us how close the nearest boundary is.
Running A Hired Generator Safely
- Outdoors only, in open air, and never inside a shed, garage, tent or enclosed space
- Well clear of doors, windows and vents, because exhaust travels further than people expect
- On firm level ground, clear of anything that will burn
- Through an RCD, with leads that are current on their test and tag
- Refuelled with the engine off and cool, never while it is running
Never Backfeed A Building
Connecting a generator to a building's wiring through a power point sends power back down the supply and can kill someone working on the network. Any connection into a switchboard is a licensed electrician's job with a proper changeover switch. If that is what you need, tell us and we will size the unit for it.
Fuel, Run Time And Getting It To Site
Run time comes from tank size against how hard the machine is working, so the same generator lasts very different lengths of time on a light load and a heavy one. We will tell you the realistic figure for your load rather than the best-case number off the spec sheet.
Units are delivered fuelled and ready to start. On a long hire we can arrange scheduled refuelling, which is worth doing: running a set dry is one of the more expensive ways to lose a morning.
Position It Before The Truck Leaves
Decide where the generator lives before delivery, because moving one across a site afterwards is a plant job, not a two-person job. It needs firm level ground, clearance for airflow and exhaust, and a cable run that is not a trip hazard.
Related Hire & Services
Air Compressor Hire Perth
Air compressor hire Perth. Towable diesel units for jackhammers, breakers and air tools, sized on cfm not just psi. Call us for a rate.
Air Compressor Hire PerthLighting Tower Hire Perth
Lighting tower hire Perth. Towable diesel and hybrid units, masts to 12m, for night works, early starts and events. Call us for a rate.
Lighting Tower Hire PerthDry Hire Perth
Dry hire in Perth - take the machine and run it yourself. Komatsu excavators and Bobcats delivered ready to work. Sharp day rates, call now.
Dry Hire PerthGenerator Hire Questions
It depends on what runs at the same time and what has a motor in it, not on the size of the site. Motors draw several times their running current at startup, so a generator sized on the sum of the labels will trip. Send us the list of what plugs in and whether you need three phase, and we will size it.
kVA is the apparent power the generator can deliver and kW is the real work it does. The gap between them is the power factor of the equipment you connect. Generators are rated in kVA, appliances are usually rated in kW, which is why sizing by matching the numbers straight across goes wrong.
Only through a proper changeover switch installed by a licensed electrician. Plugging a generator into a power point to backfeed the wiring is illegal and can electrocute someone working on the network. Tell us if standby supply is what you need and we will size a unit for it.
It depends far more on the load than on the machine. The same set that runs all day on a light load will empty its tank in a fraction of that under heavy draw. We will give you a realistic figure for your load, and on longer hires we can schedule refuelling.
Silenced units are, and they are what we recommend on a suburban block. A standard open unit is loud enough to become a neighbour complaint and on some sites a council problem. Tell us how close the nearest boundary is when you book.

Need Generator Hire In Perth?
We prefer calls, get straight through to the team. Reliable machines. Experienced operators. Jobs done right.